EPC - 792

Date : 26 June 2008

EPC792 Highlights

EPC792 delivers enhancements and corrections for the LANSA for the Web Administrator.

EPC792 and EPC791 should be considered as a pair of EPCs to be installed along with EPC790.

Several enhancements and fixes described in other EPCs (790 and 791) require EPC792 to complete the support and/or correction, including the following items :

  • new weblet std_largelist
    • Support for large lists when using the new weblet std_largelist. std_largelist is delivered in EPC790. To run a WAM that uses std_largelist, you must first use the Web Administrator (updated in this EPC792) to enable output pre-formatting.
  • disappearing layouts
  • non-responding first connection
    • A new option "Connection Check" enables multiple attempts to detect a non-responding TP job. This option completes the support for first connection failure issue described in EPC791.

ProductLANSA for the Web - Web Administrator
Version11.3
Pre-Requisite DetailsEPC773 (CU3)
Co-Requisite DetailsEPC791 must also be applied before EPC792
Related ProductsVisual LANSA
Full Distribution InV12.0
Special NotesThis EPC requires EPC790 to be applied to the application server.
User Actions 
Patches The following Hotfixes will be replaced by this EPC:

< no hotfixes have been issued for the Web Administrator >

If you have applied a patch to your environment that is not listed here contact your local LANSA vendor for instructions before applying the EPC.

Description

This EPC provides enhancements and fixes to the LANSA Web Administrator as detailed in "EPC792 includes this change".

Instructions to install the EPC

EPC792 installs directly from the self-extracting zip file in which it is delivered.

  1. It is recommended to backup your LANSA webutil folder before applying this EPC. Refer to 4.8.1 Choose Root Directory in the LANSA Online documentation for the directory where the LANSA software has been installed.
  2. Before installing the EPC you should stop using the LANSA development environment and stop all currently executing LANSA applications. If the EPC install finds files locked when it attempts to replace them a warning will be issued and the install will stop.
  3. Double-click on EPC792.exe.
  4. A message box will be displayed from which you should select the "Setup" button or "Cancel" if you do not want to proceed.
  5. If you have multiple configurations installed:
    • Before the EPC is installed a dialog box will be displayed listing the available LANSA configurations on your machine. Select the configuration to which the EPC is to be applied.
    • When you have selected the correct configuration and pressed OK the EPC will be installed.
  6. Details of the EPC are recorded. You can view these details by using the Help/Product Information menu option from inside the LANSA development environment, then click the EPC button.

Detailed changes

EPC792 includes this change:    [Click here to Show table...]

EPC792 supersedes EPC786 which addressed the following issues:    [Click here to Show table...]

List of affected objects

Windows Components:    [Click here to Show table...]

© 2006 LANSA

Back to Top