MQBIF's cannot be used with the RDMLX specific JSM(X) BIFS

Date:23 May 2008
Product/Release:LANSA Integrator
Abstract:Using MQBIF's with RDMLX (JSMX BIFS)
Submitted By:LANSA Technical Support

Currently, in order to use MQBIF's with RDMLX, it is required that you utilise the JSM BIFS not the JSMX BIFS.

The Data Queue programs in LANSA Integrator, namely JSMDQGET and JSMDQPUT, cannot be used with the RDMLX specific JSM(X) BIFS.

MQBIFs by default, require dedicated handlers to work, hence JSM_OPEN (NOT JSMX_OPEN) has to be used. JSMX_OPEN, on the other hand, uses Multiple Handlers, hence is unusable with MQBIFs

JSMDQGET and JSMDQPUT actually utilise the MQBIFS and currently MQBIFs can only be used with the RDML JSM BIFs not the RDMLX JSMX BIFs.