WAM treeview issue introduced in EPC845 causes incomplete display of Processing Sequence Log in Console
| Date: | 21st August 2009 |
|---|---|
| Product/Release: | LANSA Composer |
| Abstract: | WAM treeview issue introduced in EPC845 causes incomplete display of Processing Sequnce Log in Console |
| Submitted By: | LANSA Technical Support |
Description:
EPC845 introduces an issue for the Processing Sequence log display in LANSA Composer's Operations Console. This affects both IBM i and Windows backend.
Specific WAM related changes in EPC845 causes TreeViews in WAMS to be parsed incorrectly. In LANSA Composer's Operations Console, the result is that the Processing Sequence Log display appears to be empty.
Solution:
This has been rectified in EPC 848 for each Server type (Windows and IBM i) which fixes the parsing issue.
Note: If the symptoms still persist after applying the patch, then most likely, you will need to clear the cache on the Browser.
Additionally if the Server is Windows, then the following folders may need to be cleared as well:
<Root Drive>:\<LANSA FOLDER>\WebServer\IISPlugin\xsl.cache<Root Drive>:\<LANSA FOLDER>\X_WIN95\X_LANSA\x_<PARTITION NAME>\web\document.cache
Note: This issue can potentially cause issues anywhere treeviews are used - i.e. it is not only restricted to LANSA Composer.