User ID is missing when installing LANSA Integrator on iSeries

Date:3 July 2007
Product/Release:LANSA Integrator V11.3
Abstract:When installing LANSA Integrator on iSeries, user ID (output field) is missing
Submitted By:LANSA Technical Support

Description:

When installing LANSA Integrator on an existing LANSA for iSeries system, the install program displays the User ID that will be used as 'Integrator User ID'. This is for read-only/display information only. However if this value is blank, the install submit will fail.

Solution:

The required value (default User ID for system) is missing from the data area DCXLOADA01

Field/ItemLengthFromToDescription
USER10806815Default user

This User ID is taken as a default user profile for integrator when installed on an existing LANSA system. In the data area this positions would most likely be a blank value. This has to be filled with a User ID (DC@PGMLIB by default) that will be used for the Integrator install.

CHGDTAARA DTAARA(DCXLOADA01 (806 10)) VALUE(DC@PGMLIB)