LCE0037 error when using Web Editor against Windows server
Date: | 18 August 2003 |
---|---|
Product/Release: | LANSA for Web |
Abstract: | Receive error LCE0037 when using Web Editor |
Submitted By: | LANSA Technical Support |
Last Review: | December 2010 |
Description:
Receive error LCE0037 when using Web Editor in a Web on Windows installation.
Solution:
A known cause of this error is when LANSA internal file definitions have been recompiled in Visual LANSA.
Check to see if the dlls DC_Fnn/DC_Wnn/DC_Xnn.dlls exist in the ...\X_WIN95\X_LANSA\X_ppp\EXECUTE.
These dlls should only exist in the ...\X_WIN95\X_LANSA\EXECUTE directory. Ensure that they already exist in the ...\X_WIN95\X_LANSA\EXECUTE directory.
Remove/delete the copies from the partition execute directory (i.e. ...\X_WIN95\X_LANSA\X_ppp\EXECUTE) and the problem should be resolved.
Cause:
These internal file definitions have been recompiled with Visual LANSA, and the file definitions IOM (located in the partition execute directory) are being found and used first instead of the real internal file definitions IOMs (located in the x_lansa directory).
Note: In V10.0, a change has been made so that these internal files will no longer displayed by default, and thus should not be available for compile unless the option to display the internal files is enabled.